Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.
Medium-density foam is applied as low or high-pressure two-component polyurethane spray foam. Medium-density foam offers specific benefits depending on the climate and the type of building in which it is used. Like low-density foam, medium-density SPF is often used for continuous insulation, interior wall cavity fill, and unvented attic applications. However, medium-density is a closed-cell spray foam; it is often used where there is need for the greatest R-value insulation per inch possible. Medium-density foam acts as an air, vapor, and water barrier, and can even help reduce noise.
This high R-value of 4.45 at 1 inch, polyurethane insulation expands to seal cracks, gaps, and voids in attics, walls, crawl spaces, and ceilings. Agribalance is a three-quarter pound density foam that reduces air leakage by improving energy efficiency, and reducing moisture intrusion and outside contaminants such as dust, dirt, and allergens. As a result, builders can generally install smaller, more energy-efficient HVAC systems and achieve similar, or superior comfort compared to traditionally insulated structures which require a larger, less efficient HVAC system – resulting in higher energy costs.
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
I was hesitant to buy this because many reviews stated that it didn't cover as advertised, but after reading/following all directions, everything turned out perfectly. It even seemed to apply slightly more than the 650 bd/ft that was advertised. The application process was very easy to learn and I applied all of the product in about 1 hour and 10 minutes- prep time included. I couldn't be happier and I purchased another kit this morning.

How Much Is Spray Foam Insulation Per Sq Ft


Amanda previously has worked as a breaking news and crime reporter, TV news producer, and editor in Flint and Detroit. Throughout her career as a journalist, she has won several awards from the Detroit Chapter of Society of Professional Journalists and the Michigan Press Association. As part of the RetroFoam of Michigan family, Amanda uses her experience as a journalist to write content that will help educate homeowners on the benefits of foam insulation. When Amanda isn’t writing, she’s spending time with her husband and rescued huskies. She also loves knitting, making art, cooking, and hosting dinner and a movie night for friends and family.

How Much Does Spray Foam Weigh


Starting a new build (1 1/2 basement walkout), all 2x6 exterior walls w/ brick veneer in CZ3. Above grade, would like to do spray foam in 2x6 walls, 1/2" or 1" of rigid foam board on the exterior, and a 1" air gap. Will this require a house wrap or can I do w/o the rigid foam and go with a housewrap? Also, any recommendations about insulation strategies for the finished basement. Thanks! http://youtube.com/e/ggLAUsiuI_o
RE: my June 12 post...We went ahead and had the attic sprayed with a Soy-based product. Stayed in a hotel for 3 nites. Still smelled a little bad but that's gone away over time. I'm very glad we didn't use the other foam as even that much outgassing of a petrochemical could have sent my wife to the hospital. Unfortunately, the spray crew didn't speak English(at least not to me) and were kinda lazy, so they ended up spraying over some can fixtures from the kitchen below that were not insulation-contact rated. So I hired an electrician to come out, pull down the cans, pull out what he thought was an appropriate amount of foam to create a big enough air space and then re-install the cans. I billed the firm for the electrician plus an extra night we had to stay in the hotel and they paid, no questions asked. Guess they knew they had screwed up.   

The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit. 

Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.
The roof must be thoroughly cleaned, and allowed to dry thoroughly. This is a critical step to ensure a successful coating application. Be careful not to damage the lap seams. Care should be taken when pressure washing not to disturb the integrity of the underlying roof membrane particularly where there are adhered seams. Refer to the specific coating manufacturer you are using for their specific requirements for roof preparation.

This depends on the geographic location, insulation, and cost of electricity. Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL), National Roofing Contractors Association (NRCA), and several roofing material manufacturers have computer programs that can estimate the savings. A growing number of energy consultants are available to provide environmental regulation compliance information. 

This high R-value of 4.45 at 1 inch, polyurethane insulation expands to seal cracks, gaps, and voids in attics, walls, crawl spaces, and ceilings. Agribalance is a three-quarter pound density foam that reduces air leakage by improving energy efficiency, and reducing moisture intrusion and outside contaminants such as dust, dirt, and allergens. As a result, builders can generally install smaller, more energy-efficient HVAC systems and achieve similar, or superior comfort compared to traditionally insulated structures which require a larger, less efficient HVAC system – resulting in higher energy costs.
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.
Current guidelines recommend up to 10 inches of insulation in your attic . This is usually added to the ground, rather than the roof line, which results in the loss of your storage area, due to not being able to refit floor boards after installation. By implementing spray foam insulation to the roof line, you regain the lost 10 inches, thus increasing storage, height and practicality.
Spray polyurethan foam does effectly prevent all six of these heat transfer methods from occurring. These should be the mechanisms by which you judge insulation, in addition to their R-Value. If you're uncertain about installing spray foam insulation, Energy Star has a map that recommends levels of insulation by R-value and cost-effectiveness in the United States.
If you're chemically sensitive, it's probably not a good idea to get it installed, but it's also not a good idea to breathe musty air from the crawl space either. In addition, your house and its contents are made of lots of materials that affect your indoor air quality. If you're really concerned about this, hire a company to test your air and tell you what you can do about it. 

Spray polyurethane foam, or SPF, is the main type of 2-part, closed-cell spray foam used by insulation contractors. Large-scale insulation jobs require special equipment as well as safety gear to protect the installer from chemical fumes during installation. When the foam cures and hardens just several minutes after application, it's completely safe for as long as it stays in place.
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close