c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

How Much Is Spray Foam Per Sq Ft


Apply coating when the roof is dry and the sealant has set. You will be using a 9-inch heavy-duty frame, ½-inch paint roller for spreading coating on roof or 1-1/4-inch roller for dipping in pail, and a 5–to-6-foot extension pole. Use a 3/4-inch roller with basecoats and emulsions. Map out your roof and make each pail fill that area. See Elastek Product Sheets for recommended coverage. An inexpensive 3-inch or 4-inch brush should be used to reach areas not possible with a roller. Use a stiff paintbrush for applying 103 Crack & Joint Sealant.
Jennifer, I'm not an expert on the health effects of closed cell foam. A lot of people live in houses with closed cell foam and have no health problems from it, at least not short-term, acute problems. I do know of one person who had it removed from her crawl space because she was convinced it caused her dog to get sick, but I know only what she told me.  
Find spray foam contractors, suppliers, equipment, news, and technical information about spray foam insulation, foam roofing, and protective coatings. If you are a homeowner, builder/architect, or interested to get into the spray foam business, we have set-up special areas just for you. Check out our information packed Spray Foam Guides to learn more.

As mentioned above elastomeric coatings can be used to fix almost all types of roofs. Examples of common roof types that will work well with elastomeric coatings include; wood, polyurethane foam, single-ply roofing, modified bitumen, metal roofs, concrete and built-up roofing. If you aren't sure your roof type will work well elastomeric coatings, do not hesitate to contact us. Our experts are always willing to help.


Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)

Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.

The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials.


You probably have some familiarity with spray foam insulation, and you may have even used the foam that comes in pressured spray cans at home improvement retailers. This foam is know as one-part foam, meaning that it is one continuous mixture that is simply applied to the area in need. One-part foam is frequently used for sealing small gaps and cracks.
KARNAK manufactures a complete line of sustainable roof coatings, sealants, and waterproofing solutions certified to comply with UL, FM, CRRC, ENERGY STAR®, Dade County, Title 24, and Florida’s HVZ building code. Our ENERGY STAR-labeled coatings can help buildings obtain LEED points. With four factories and seven warehouses across the U.S., KARNAK’s dedicated sales and customer service team will deliver the products you need in less time than it takes our quick-dry 535 Envirolastic to cure.

How Much Is Open Cell Spray Foam Insulation


Spray foam insulation works by sealing the building envelope to stop conditioned air from escaping and prevent unwanted outside air from entering your home. It allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. It's a lightweight, durable, and versatile insulation solution boasting the industry’s strongest performance in energy efficiency and energy cost savings. http://youtube.com/e/ggLAUsiuI_o?app=desktop
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors.

Spray foam insulation is typically priced by volume, meaning your cost will depend on how much material you need to use to insulate your space, although other factors may influence price as well. In most cases, the cost of spray foam insulation is more than worth it, as it's a once and done upgrade that will not only provide energy savings in your home, but also improve your home's overall comfort.

Spray Foam Existing Wall


The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.
Spray foam insulation works by sealing the building envelope to stop conditioned air from escaping and prevent unwanted outside air from entering your home. It allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. It's a lightweight, durable, and versatile insulation solution boasting the industry’s strongest performance in energy efficiency and energy cost savings.

Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct? https://www.youtube.com/v/ggLAUsiuI_o&feature=kp
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article.
If you don't have the patience to slowly fill the void with spray foam through holes drilled in one of the studs, you could (if you were an experienced carpenter) use a Sawzall to remove one of the studs and re-frame the corner as a two-stud corner. Then you could either insulate the void with a fiberglass batt or simply present the two-stud corner to the spray-foam contractor as an accessible corner.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
I have never used foam insulation before and this was easy for me to use right out of the box. I had a 4'x8"x8" cavity in my basement that houses a waterline. When the previous homeowner installed this they put no insulation in at all and being that it's an exterior wall in the basement and I live in the Midwest that thing was pushing so much cold air in it was incredibly uncomfortable. Out of the box and job completed in about 5 minutes. Stopped all drafts and created a nice 2" barrier on the wall in which I will install some extra bat insulation over it. 4 stars because the spray isn't very good passed 6-8" from the surface. Make sure you can reach the surface you want to coat. Great for small jobs!
Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.
We service the entire Central Texas Area including Waco, Abilene, Fort Worth, as well as Granbury, Aledo, Weatherford, Eastland, Hico, Hamilton, Brownwood, Comanche, Glen Rose, Meridian, Cleburne, Mineral Wells, Graham, Breckenridge, Decatur, Eastland, Ranger, Gorman. We have done work as far away as Colorado, so don't hesitate to call if you're outside this immediate area.
The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.
Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners. http://www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

I did a LOT of prep before using this product. Cleaned, vacuumed, installed additional insulation etc etc etc. This spray foam was easy to work with, and did it's job as it was supposed to. If you are curious, this kit was purchased because - every "foam insulation company" I contacted either did not call back (due to no interest) OR this was too small of a job. That is why I went DIY on this one, that and: I was advised by one of these companies that they have a minimum $2k job because ... (insert your answer here, but I will choose that everyone needs to eat).
Spray foam insulation works by sealing the building envelope to stop conditioned air from escaping and prevent unwanted outside air from entering your home. It allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. It's a lightweight, durable, and versatile insulation solution boasting the industry’s strongest performance in energy efficiency and energy cost savings.
Foam is very sticky; you'll need to wear disposable coveralls with a hood, and gloves, a face mask, and eye protection. It takes some practice to spray foam evenly and, because it expands so dramatically, to control its depth; 2 inches is all you need to seal the joist cavities. You need a clear area so that you can work without interruption; any pause longer than 30 seconds will clog the nozzle and require putting on a new one. It's also critical that the air temperature stays between 75 and 85 degrees.
Polyurethane Spray Foam Insulation is used in industries ranging from mining to movies, from cold storage to marine flotation. Spray Foam Insulation’s ability to seal out air and insulate quickly means it’s always in high demand for residential and commercial applications. Spray Foam Insulation is critical for solving our nation’s energy challenges because it dramatically reduces the energy needed to heat and cool our homes and offices. https://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
You probably have some familiarity with spray foam insulation, and you may have even used the foam that comes in pressured spray cans at home improvement retailers. This foam is know as one-part foam, meaning that it is one continuous mixture that is simply applied to the area in need. One-part foam is frequently used for sealing small gaps and cracks.

Spray Foam Basement Walls Cost


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
Sporadic cases of hypersensitivity pneumonitis (HP) have also been reported in workers exposed to isocyanates. The symptoms may seem like the flu, with fever, muscle aches, and headaches. Other symptoms may include a dry cough, chest tightness, and difficult breathing. Individuals with chronic HP often experience progressively more difficult breathing, fatigue, and weight loss. Individuals with acute HP typically develop symptoms 4–6 hours after exposure.[4]

How Much Is Spray Foam Insulation For Attic

×