I had a hole in the drywall in our bathroom that was about 2 in x 5 in that I used Great Stuff to fix. I am impressed with the characteristics of the filler. It filled the hole completely in a few seconds of application. I will warn anyone using it though to make sure you don't fill the hole entirely flush to the wall because this stuff continues expanding after you apply it. I didn't think about that but no big deal really because you can sand it which is exactly what I did, and then applied spacial and paint and it is almost as good as new. For the price this was a heck of a deal because I only used a tiny amount and now am left with nearly a full can. I guess I will have to find somewhere else to use it now. Great product, ... full review
Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners.
Today, each of the 50 states follows a different set of building codes making navigating these codes confusing, particularly for architects or builders that have projects in multiple states. In some cases, the building code changes significantly between the state and certain cities or counties within the state. For example, at the time of writing Arizona had adopted the 2015 IRC Building Code, however, Phoenix was on the 2012 IRC, IBC and IECC code. With the majority of states either on the 2009, 2012 or 2015 code, below are some high-level points to consider and about how spray foam insulation contributes. http://www.youtube.com/v/ggLAUsiuI_o
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof?

This high R-value of 4.45 at 1 inch, polyurethane insulation expands to seal cracks, gaps, and voids in attics, walls, crawl spaces, and ceilings. Agribalance is a three-quarter pound density foam that reduces air leakage by improving energy efficiency, and reducing moisture intrusion and outside contaminants such as dust, dirt, and allergens. As a result, builders can generally install smaller, more energy-efficient HVAC systems and achieve similar, or superior comfort compared to traditionally insulated structures which require a larger, less efficient HVAC system – resulting in higher energy costs.
Porch urns are an excellent way to add seasonal curbside flair. However, tall items such as twigs, birch stems or even pumpkins can sway in the breeze and make a mess of your carefully planned decor. To prevent things from shifting, place your items in the container and spray around them with expanding foam to create a comfy nest that will keep your urns looking great. Place a layer of moss, hay or greenery on top to finish the look.

Spray Foam Garage Door


These coatings contain various types of acrylic polymer, and are typically formulated to help extend the coating’s life and improve durability. Acrylic coatings are available in a number of colors but are most commonly used as white reflective coatings. Thanks to its durability and low cost, many contractors and facility managers believe this to be the best roof coating.
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost. https://youtube.com/watch?v=ggLAUsiuI_o&app=desktop
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.
Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close
If you haven’t considered spray foam insulation, now may be the time to start looking into it. As you know, having proper insulation will help reduce your heat and air conditioning bills. In specific, spray foam insulation can be particularly helpful during renovations. It can provide a barrier between outside walls, and even a sound barrier for the inside.
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article.
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.). http://youtube.com/v/ggLAUsiuI_o?version=3
SPF, a spray-applied cellular plastic, is made by mixing chemicals to create foam. Those chemicals react very quickly, expanding on contact to create foam that insulates, air seals and provides a moisture barrier. When properly installed, SPF forms a continuous barrier on walls, around corners and on contoured surfaces. It resists heat transfer very well and is an effective solution for reducing unwanted air infiltration through cracks, seams, and joints.

Air infiltration and exfiltration within a home contributes to almost 99% of moisture migration. Restricting air movement stops moisture accumulation so that the possibility of mold growth is less likely. Combined with a properly sized HVAC system, spray foam insulation helps control the indoor humidity levels to minimize moisture and condensation. Reducing moisture and controlling humidity can also add years to the life expectancy of a home, plus contribute to a healthier indoor environment. Finally, it also deters pests, making it difficult for them to nest.


Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.
I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks.

Spray Foam Professionals


Spray foam insulation, also known as foaming insulation or sprayed insulation, is a two-part liquid insulation material that insulates and air seals wherever it is applied. The material comes in two large 55 gallon drums – an iso and a resin. These two liquids are kept separate until applied at the jobsite by a qualified, licensed spray foam installer. The two liquids travel up through a heated hose to the spray gun where they are combined to create the foam. The foam expands within seconds to fill the cavity surface.  Depending on the type of sprayed-in foam insulation used, closed-cell or open-cell, the foam expands between 40 and 100 times its size upon application. 
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids.
once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close

Roof Coating Seal

×