If you don't have the patience to slowly fill the void with spray foam through holes drilled in one of the studs, you could (if you were an experienced carpenter) use a Sawzall to remove one of the studs and re-frame the corner as a two-stud corner. Then you could either insulate the void with a fiberglass batt or simply present the two-stud corner to the spray-foam contractor as an accessible corner.
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  
Here's a simpler, less expensive alternative: Cut some 2-inch-thick rigid-foam insulation and glue it to the subfloor between the joists or support it with nails driven partway into the joists. Then fill any gaps between the edges of the foam boards and the joists using the canned spray foam sold at home centers or hardware stores. An even easier option is to nail the foam panels against the bottom edge of the joists and seal the joints with canned foam, but you'll lose some headroom and access to any pipes and wires between the joists. As with spray-foam kits, protect yourself and the floor from the dripping globs of canned foam. A full face shield, gloves, and a hat would be a good start.
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .
Polyurethane Spray Foam Insulation is used in industries ranging from mining to movies, from cold storage to marine flotation. Spray Foam Insulation’s ability to seal out air and insulate quickly means it’s always in high demand for residential and commercial applications. Spray Foam Insulation is critical for solving our nation’s energy challenges because it dramatically reduces the energy needed to heat and cool our homes and offices. https://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides). https://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata
The roof must be thoroughly cleaned, and allowed to dry thoroughly. This is a critical step to ensure a successful coating application. Be careful not to damage the lap seams. Care should be taken when pressure washing not to disturb the integrity of the underlying roof membrane particularly where there are adhered seams. Refer to the specific coating manufacturer you are using for their specific requirements for roof preparation.
We are your allies in the victory over energy loss. Our mission is to educate our clients and community on the rewards of energy efficiency using a combination or the straight forward Sprayfoam insulation solution. By evaluating the needs of the development planned structures, budgets involved, and goals of the builder or individual homeowners, we compose a comprehensive work scope designed to tighten the thermal envelope and improve indoor air quality and acoustics, all while lowering operating costs and still creating homes that breathe. With over 50 years of combined experience and pages of 'Home Energy Reports' with 98% energy loss numbers — we help you begin your journey of offering homes energy independence and extreme comfort.   https://m.youtube.com/e/ggLAUsiuI_o
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.
The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.  
For maximum durability and leak resistance, we recommend that two coats of topcoat be applied at 100 sq. ft. per gallon, or a minimum of 20 mils dry coating. If two complete topcoats are not applied, always apply two thick coats to problem areas such as scuppers, drain areas, ponding areas, seams, and repaired areas. Avoid using Elastek Solar Magic™ or The Shield™ on ponding roofs. Clean skin and tools promptly with water.

KARNAK manufactures a complete line of sustainable roof coatings, sealants, and waterproofing solutions certified to comply with UL, FM, CRRC, ENERGY STAR®, Dade County, Title 24, and Florida’s HVZ building code. Our ENERGY STAR-labeled coatings can help buildings obtain LEED points. With four factories and seven warehouses across the U.S., KARNAK’s dedicated sales and customer service team will deliver the products you need in less time than it takes our quick-dry 535 Envirolastic to cure.
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.

Spray Foam


Due to its relatively large cell structure, low-density foam stays somewhat soft and flexible after curing. This increases the likelihood of its continuing to provide high insulation value even as the building settles and shifts over time. Low-density SPF provides heat insulation and seals airflow through cracks, joints and seams by filling the cavities. In addition, this foam can help absorb sound thanks to its soft texture and open-cell structure.
Silicone based coatings can be spray or roller-applied, and should utilize a medium-nap roller when rolled. These coatings are applied anywhere from 2 to 3.5 gallons per 100 square feet, depending on the substrate. Silicone has two major advantages over the other four types of coatings that should be considered when searching for the best roof coating: 1) it can resist ponding water for extended periods of time and 2) it can adhere to most substrates without a primer. Because of these two major advantages, silicone is the best roof coating that satisfies both quality and cost-effectiveness. 

Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners. http://www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
One thing I wanted to mention was that I think your price point is a little high and that might deter people from considering spray foam. As a project manager for a spray foam company for years I can tell you that we offer 0.5 Lb. open-cell foam at around $.25/board foot. We even offer a 1.0 Lb. open-cell foam for less/the same cost as you quoted the 0.5 Lb. foam for above. The 1/0 Lb. open-cell foam has an R-value of almost 5.
Even for these unique circumstances, InsulBloc is an excellent barrier to dust, drafts, pollen, and noise pollution. This sustainable product is once installed seals any construction gaps or tiny cracks to block heat flow bypass of the insulation membrane. All of this means InsulBloc® outperforms every other insulation system on the market, providing superior operational energy and cost savings.
Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings. https://m.youtube.com/embed/ggLAUsiuI_o
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
Foam is very sticky; you'll need to wear disposable coveralls with a hood, and gloves, a face mask, and eye protection. It takes some practice to spray foam evenly and, because it expands so dramatically, to control its depth; 2 inches is all you need to seal the joist cavities. You need a clear area so that you can work without interruption; any pause longer than 30 seconds will clog the nozzle and require putting on a new one. It's also critical that the air temperature stays between 75 and 85 degrees.
I used this product to seal and insulate my rim joists as I am finishing the basement. The builder used R13 batt insulation when we built the house 3 years ago. I use a dehumidifier to control moisture in the basement which is below grade. The setting I use is 55%. The dehumidifier kicks on periodically and requires emptying every few days. Since using the foam all around the house on the rim joists and sill plate, the dehumidifier has stayed at 50% for over two weeks since spraying and rarely turns on anymore. I also put the original R13 batt insulation back up after the foam cured. 

How Much For Spray Foam Insulation


Low-density foam is applied as low or high-pressure, two-component polyurethane spray foam. Low-density spray foam can be applied on walls, in unvented attics, to ducts and ceilings, and in vented attics and crawl spaces. It is known as an air barrier, but permeable to vapor and moisture. It is often used to fill cavities in walls during construction.
once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides). https://m.youtu.be/ggLAUsiuI_o
a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.
For maximum durability and leak resistance, we recommend that two coats of topcoat be applied at 100 sq. ft. per gallon, or a minimum of 20 mils dry coating. If two complete topcoats are not applied, always apply two thick coats to problem areas such as scuppers, drain areas, ponding areas, seams, and repaired areas. Avoid using Elastek Solar Magic™ or The Shield™ on ponding roofs. Clean skin and tools promptly with water.
Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]

How Much Does Spray Foam Insulation Cost

×