While coatings may potentially stop minor leaks, the roof should be properly repaired and dried prior to coating application. Coatings may be able to seal pinhole leaks, which are leaks not visible to the naked eye. If the roof is leaking, the roof leak will need to be identified and repaired prior to any recoating; do not expect the coating to find and seal the leaks.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

How Much Is Spray Foam Insulation A Square Foot


Sealection® 500 has been Demilec's flagship product for more than 20 years, and has positioned Demilec as an industry-leading spray foam insulation manufacturer. As an environmentally-friendly product, it delivers superior performance, energy savings, and is an excellent return on investment for architects, builders, contractors, and homeowners, making it the ideal choice for insulation.
I just received this and it worked well for me. It works well for small gaps (around windows, between studs), but probably not the right tool for larger gaps (>1" or 2"). If used in larger gaps, it works OK if it is layered in. Spray a little and wait for it to set, then layer another on top, etc... This is pretty much noted by the seller. It is pretty much exactly as described and priced right, so 5 stars. If you need to do larger gaps, buy 2 part. http://www.youtube.com/e/ggLAUsiuI_o?app=desktop
With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.

The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials.
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.

There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit.
Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. https://www.youtube.com/v/ggLAUsiuI_o&feature=share
Demilec, a company located in Texas, has invented a type of insulation foam that can help all of the cracks and uneven pavement problems. Geolift can help to lift existing concrete surfaces and fix those problem areas around your house with much less labor. Geolift works for driveways, sidewalks, patios, garage floors, even pool decks. And yes, it is a foam, just like your beloved spray foam!
A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]

Roof Spray Foam Insulation

×