Find spray foam contractors, suppliers, equipment, news, and technical information about spray foam insulation, foam roofing, and protective coatings. If you are a homeowner, builder/architect, or interested to get into the spray foam business, we have set-up special areas just for you. Check out our information packed Spray Foam Guides to learn more.
Carefully examine the roof membrane (surface material) for cracks, tears, blisters, evidence of ponding, exposed foam, and open seams. If already coated, evaluate the condition of the coating. Pay particular attention to areas around roof penetrations (vents, skylights, pipes, etc), ponding areas, cracks in parapet walls, and the attachment of roof membranes to parapet walls. Roofs should be in good condition to warrant coating.

In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.

How Much More Expensive Is Spray Foam


Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.
Water-based acrylic coatings have more than 30 years of proven performance over a wide range of substrates. It is the coating of choice for metal roofs since it is highly reflective, can be easily tinted and is not extremely slippery when damp. When used with our rust primer, even rusted roofs can be saved. TIP: If you have a metal roof or a low slope roof that doesn't pond water, consider acrylic coatings. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]
DID YOU KNOW? Spray FOam insulation out-performs conventional insulation materials because they (conventional insulation materials) trap still-dry air and if that air moves or becomes wet, the thermal resistance can drop by 50%. Spray Foam protects against air infiltration, which can increase energy costs in buildings by 10 to 40%. Eliminate these drafts and live in a more energy-efficient, comfortable and healthier building by choosing spray foam insulation.
I started watching back in the Bob Villa days. It's funny when Bob left the show I thought well that's the end of my favorite show. I couldn't have been more wrong. TOH has gotten better and better over the years. I've gotten so many great ideas for my houses from watching close to every episode of TOH. Also, my confidence in being able to take on more and more complex projects at home has grown thanks to Norm, Tommy and Roger. Sorry Richard, I love watching you and learning about the latest greatest plumbing, heating and cooling tech but I hate doing plumbing stuff. My favorite projects would be #1 Carlisle House in 2004 and #2 Cambridge House in 2005. I've watched those seasons multiple times since becoming an Insider. Kevin is by far my favorite TOH host. His first couple of seasons were rough but once he hit his stride he just got better and better. I absolutely love it when Kevin and Tommy do their 'Sonny and Pops' routine. Who wouldn't want Tommy Silva to be their Pops! Thank you for 40 great years!

Spray foam insulation is a great product. Homes insulated with it can be some of the most efficient and comfortable homes built. I've been in plenty of these homes and can tell you that when spray foam is installed properly, they outperform 99% of fiberglass batt-insulated, stick-built homes. (I can also tell you that 73% of all statistics are made up on the spot, so please don't ask for documentation of that statistic.)


Empire Spray Foam is conveniently located in North Texas and proudly serves the Tarrant, Dallas, Denton, Wise, Parker, Hood, Johnson, Ellis, Kaufman, Rockwall, and Collin Counties with high quality spray foam and coatings designed to meet the needs of homeowners and businesses. Whether you are looking for energy savings, structural reinforcement, or weatherproofing, we have the solution. Call today to discuss your spray polyurethane foam options 817-516-2014.

Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include:
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.). http://youtube.com/v/ggLAUsiuI_o?version=3
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.

Spray Foam Attic Insulation


Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]
Both high and low-pressure, two-component spray foam are applied by professional contractors who are trained to use and apply SPF with the required equipment (protective gear, full eye protection, respirators, and gloves). Contractors should follow the ventilation recommendations by the product manufacturer to avoid overexposure through inhalation, and instruct those without protective gear (homeowners or building occupants) to stay away from the work area during exposure times and to not return until instructed by the professional contractor.
Note:  A board foot is defined as a 12" x 12" square at 1" thick. Actual output can be affected by a number of factors including temperature and humidity. The theoretical yield has become an industry standard for identifying certain sizes of two component kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into account the loss of blowing agent or the variations in application methods and types.

How Much To Spray Foam A Pole Barn

×