I have been looking to have closed cell insulation added through out my attic space. I cant seam to find a installed that wants to install no more than 2 inches, and thats not near my R-valve for South Carolina (Lake Greenwood)please send any advice that will help me to see what installer will perform the correct job. This is a expense that i can only afford to do once. Sandi

Water-based acrylic coatings have more than 30 years of proven performance over a wide range of substrates. It is the coating of choice for metal roofs since it is highly reflective, can be easily tinted and is not extremely slippery when damp. When used with our rust primer, even rusted roofs can be saved. TIP: If you have a metal roof or a low slope roof that doesn't pond water, consider acrylic coatings.


Silicone coatings are typically produced by adding a catalyst and solvents to a silicone base. Because the silicone is a natural material, these coatings are bio-degradable. They can be applied to a roofing system using many different techniques, including spraying or rolling. Silicone coatings are available in many colors, including reflective white and translucent. 

Our commitment to using intelligent solutions and high-performing, quality products to help solve global environmental challenges is evident in both the use of renewable and recycled content in our products, as well as our green recognitions and certifications by various organizations, such as the NAHB Research Center, LEED Certifications, and USDA Bio-Preferred, just to name a few. http://www.youtube.com/watch?feature=youtube.be&v=ggLAUsiuI_o
KARNAK manufactures a complete line of sustainable roof coatings, sealants, and waterproofing solutions certified to comply with UL, FM, CRRC, ENERGY STAR®, Dade County, Title 24, and Florida’s HVZ building code. Our ENERGY STAR-labeled coatings can help buildings obtain LEED points. With four factories and seven warehouses across the U.S., KARNAK’s dedicated sales and customer service team will deliver the products you need in less time than it takes our quick-dry 535 Envirolastic to cure.

Spray Foam Companies


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
I just received this and it worked well for me. It works well for small gaps (around windows, between studs), but probably not the right tool for larger gaps (>1" or 2"). If used in larger gaps, it works OK if it is layered in. Spray a little and wait for it to set, then layer another on top, etc... This is pretty much noted by the seller. It is pretty much exactly as described and priced right, so 5 stars. If you need to do larger gaps, buy 2 part. http://www.youtube.com/e/ggLAUsiuI_o?app=desktop
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids.
2. I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. I would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing.
We service the entire Central Texas Area including Waco, Abilene, Fort Worth, as well as Granbury, Aledo, Weatherford, Eastland, Hico, Hamilton, Brownwood, Comanche, Glen Rose, Meridian, Cleburne, Mineral Wells, Graham, Breckenridge, Decatur, Eastland, Ranger, Gorman. We have done work as far away as Colorado, so don't hesitate to call if you're outside this immediate area.
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners. http://www.youtube.com/watch?v=ggLAUsiuI_o&app=desktop

I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.
Get the Power to Seal & Insulate Perfectly in Just 5 Minutes. The Foam it Green Promise: 1>Simpler, Easier, Faster Spray Foam 2>No Special Skills or Know How 3>Professional Results or Better Saves You Time, Money and Hassles. Delivers to your door, ready to use. Just follow the simple instructions. Saves Energy with High R-value Closed Cell Foam. R-Value of 7 in Just 1 Inch. Provides a seamless air barrier in 1 step. This Kit Provides Approx. 602 Square Feet at 1” thickness of cured foam. Class I E-84 Fire-Retardant Foam that meets building code specs. This Anti-Microbial Formula passed the stringent ASTM G-21 test for preventing mold growth on the surface of the foam. Includes everything you need to complete your project. Weighs 120 lbs, including steel canisters pressured with nitrogen. Orders with multiple kits on it may ship via LTL instead of UPS. The LTL carrier calls to arrange a convenient delivery time. Usually Ships Same Business Day. See Manufacturer for returns and warranty policy.

We have a 1950's ranch in Atlanta and are interviewing foam contractors to spray open cell under the roof, with an "ankle wall" out towards the eaves to seal the attic. My wife and daughters are chemically sensitive, so I'm trying to figure out how to minimize the fumes coming into the house. Additionally, at least one contractor has offered (for > $900) to remove our existing rock wool & R-13 fibreglass from the attic floor to "increase cross-ventilation into the attic". Seems to me I can't both minimize fumes AND increase cross-ventilation. They also offered to spray a fire-retardant on for >$600. Would ventilation during installation help any or woud the retardant seal off the foam and help that way? Thanks...
Foam is very sticky; you'll need to wear disposable coveralls with a hood, and gloves, a face mask, and eye protection. It takes some practice to spray foam evenly and, because it expands so dramatically, to control its depth; 2 inches is all you need to seal the joist cavities. You need a clear area so that you can work without interruption; any pause longer than 30 seconds will clog the nozzle and require putting on a new one. It's also critical that the air temperature stays between 75 and 85 degrees.
For large jobs, professionals such as Dr. Energy Saver use two-part foam, which comes in larger containers. With 2-part spray foam, it's necessary to mix separate resin and catalyst compounds at the application nozzle. Combining these ingredients starts a chemical reaction that creates expanding foam. Contractors use small 2-part foam "kits" to air-seal an attic or to seal and insulate ductwork. To insulate an entire attic or wood-framed wall with spray foam, the resin and catalyst compounds are pumped to the application nozzle from 50-gallon drums in a specially equipped truck.

Roof Coating

×