Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.

How Much Is Attic Spray Foam


In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides). https://m.youtu.be/ggLAUsiuI_o
We service the entire Central Texas Area including Waco, Abilene, Fort Worth, as well as Granbury, Aledo, Weatherford, Eastland, Hico, Hamilton, Brownwood, Comanche, Glen Rose, Meridian, Cleburne, Mineral Wells, Graham, Breckenridge, Decatur, Eastland, Ranger, Gorman. We have done work as far away as Colorado, so don't hesitate to call if you're outside this immediate area.
Today, each of the 50 states follows a different set of building codes making navigating these codes confusing, particularly for architects or builders that have projects in multiple states. In some cases, the building code changes significantly between the state and certain cities or counties within the state. For example, at the time of writing Arizona had adopted the 2015 IRC Building Code, however, Phoenix was on the 2012 IRC, IBC and IECC code. With the majority of states either on the 2009, 2012 or 2015 code, below are some high-level points to consider and about how spray foam insulation contributes.
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
2. I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. I would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing.
If you're chemically sensitive, it's probably not a good idea to get it installed, but it's also not a good idea to breathe musty air from the crawl space either. In addition, your house and its contents are made of lots of materials that affect your indoor air quality. If you're really concerned about this, hire a company to test your air and tell you what you can do about it.
I have been looking to have closed cell insulation added through out my attic space. I cant seam to find a installed that wants to install no more than 2 inches, and thats not near my R-valve for South Carolina (Lake Greenwood)please send any advice that will help me to see what installer will perform the correct job. This is a expense that i can only afford to do once. Sandi

Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.

Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage.
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.).
We are your allies in the victory over energy loss. Our mission is to educate our clients and community on the rewards of energy efficiency using a combination or the straight forward Sprayfoam insulation solution. By evaluating the needs of the development planned structures, budgets involved, and goals of the builder or individual homeowners, we compose a comprehensive work scope designed to tighten the thermal envelope and improve indoor air quality and acoustics, all while lowering operating costs and still creating homes that breathe. With over 50 years of combined experience and pages of 'Home Energy Reports' with 98% energy loss numbers — we help you begin your journey of offering homes energy independence and extreme comfort.  
Low-pressure spray polyurethane foam is typically applied around ductwork, electrical or piping penetrations, rim joists and roof repairs. This type of foam is used to insulate and seal small to mid-sized areas in homes and other buildings that are too large or extensive for smaller, insulating foam sealants. It is especially effective in weatherizing older homes that have many cracks, gaps and wall penetrations around doors, window frames, pipes and plumbing lines. The air- and heat-leakage improvements can be quite dramatic after a low-pressure SPF application, which can result in greater efficiencies.
For maximum durability and leak resistance, we recommend that two coats of topcoat be applied at 100 sq. ft. per gallon, or a minimum of 20 mils dry coating. If two complete topcoats are not applied, always apply two thick coats to problem areas such as scuppers, drain areas, ponding areas, seams, and repaired areas. Avoid using Elastek Solar Magic™ or The Shield™ on ponding roofs. Clean skin and tools promptly with water.
Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners. http://www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
Our commitment to using intelligent solutions and high-performing, quality products to help solve global environmental challenges is evident in both the use of renewable and recycled content in our products, as well as our green recognitions and certifications by various organizations, such as the NAHB Research Center, LEED Certifications, and USDA Bio-Preferred, just to name a few.
This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the “Accept All Cookies” button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy.
Polyurethane Spray Foam Insulation is used in industries ranging from mining to movies, from cold storage to marine flotation. Spray Foam Insulation’s ability to seal out air and insulate quickly means it’s always in high demand for residential and commercial applications. Spray Foam Insulation is critical for solving our nation’s energy challenges because it dramatically reduces the energy needed to heat and cool our homes and offices.

How Much Is Spray Foam


If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

Where Can I Buy Spray Foam Insulation

×